ACCESSORIES |
| |
DELTA 60
LOAD MANAGER FOR STORAGE HEATERS
The optimum refinement of a storage heater installation is the DELTA 60 charge regulator.
This device is located on the general control and safety panel of the house and enables the level of charging of the storage heater unit to be automatically regulated, depending on the night time temperature which is recorded on the outside probe supplied.
This will prevent the storage heaters being overcharged, providing maximum economy.
Suitable for:
- Dynamic Storage Heaters, ADL range.
- Static Storage Heaters, ADS, SH ranges.
Features:
- Exterior sensor is included.
- Three positions time base: 1 min, 4 hours and 8 hours.
- Adjustable temperature from 7ºC to 23ºC.
- Compatible with 14 hour time based electric tariff 2.0 DHA.
|

|
| |
|
|
| |
|
|
| AMBIENT THERMOSTATS AND PROGRAMMABLE THERMOSTATS |
| |
TA3
AMBIENT THERMOSTAT WITH MEMBRANE
Single pole adjustable thermostat, contact quick opening by temperature variation.
It includes a LED showing the open / closed circuit.
Suitable for:
- Dinamic Storage Heaters ADL range.
- Electric Boilers CM, CMX and CPE ranges.
Features:
- Single pole change over contact.
- Temperature range: 5ºC to 30ºC.
|

|
| |
|
|
|
| |
|
|
|
|
| |
CTP10
WIRED DIGITAL PROGRAMMABLE ROOM THERMOSTAT
Thermostat with both Daily and weekly programmable options allowing different combinations with three levels of temperature, comfort, economy and frost-protection.
LCD display backlit in blue showing ambient temperature, set up temperature, battery level and other information.
Optimized ergonomics.
Temperature control of a zone.
Suitable for:
- Dinamic Storage Heaters ADL range.
- Electric Boilers CM, CMX and CPE ranges.
Features:
- Blue backlight LCD display.
- Mode selector: comfort setting, economy setting and frost protection.
- Weekly and daily programming options.
- Program copying function available.
- Display of either set-point or room temperature.
- Anti-seizing function of pump (Boilers).
Technical characteristics:
- Power supply: 2 LR03 Batteries (supplied).
- Regulation: Pl or “on / off”.
- Mounting: wall-mounted, on a support or on flush-mounted box.
|

|
| |
|
|
|
| |
|
|
|
|
| |
X2D
WIRELESS DIGITAL PROGRAMMABLE ROOM THERMOSTAT
Thermostat with both Daily and weekly programmable options allowing different combinations with three levels of temperature, comfort, economy and frost-protection.
LCD display backlit in blue showing ambient temperature, set up temperature, battery level and other information.
Optimized ergonomics.
Temperature control of a zone.
Features:
- Blue backlight LCD display.
- Mode selector: comfort setting, economy setting and frost protection.
- Weekly and daily programming options.
- Program copying function available.
- Display of either set-point or room temperature.
- Anti-seizing function of pump (Boilers).
Technical characteristics:
Transmitter, E x2D:
- Power supply: 2 LR03 Batteries (supplied).
- Regulation: Pl or “on / off”.
- Mounting: wall-mounted, on a support or on flush-mounted box.
Receiver, R x2D:
Suitable for:
- Dinamic Storage Heaters ADL range.
- Electric Boilers CM, CMX and CPE ranges.
|

|
| |
|
|
|
| |
|
|
| |
| ENERGY MANAGERS |

|
ENERGY MANAGERS
The energy manager allows an optimum operation of the electric power supply. Avoiding the activation of the general power switch of the fuse box when the Utility Company add some limit to the installation demanded power. |
|
|
| |
|
|
|
|
| |
RG90
RG90, UNIVERSAL ENERGY MANAGER, 3 OUTPUTS, SINGLE PHASE
Compatible for installations using standard meters (single-phase) or electronic meters (single-phase or three-phase).
3-output load shedding.
2 inputs for the programmer.
Absence input (telephone remote control, etc.).
Suitable for conventional –or pilot wire– thermal radiators, panel heaters or direct heating in general.
Features:
- 230 V, 50 Hz power supply, +/- 10%.
- 3 rest contact outputs, 2 A 230 V.
- 2 inputs for programmers (clocks, programming control unit, etc.).
- 1 absence input (telephone remote control).
- Pilot wire-type heating selection input.
- 1 remote information connection input (output from the Electronic meter).
- Link with the single-phase or three-phase electronic meter: 1 6/10 single twisted pair cable with continuity wire, max. length 100 m.
- Display of the state of the dialogue with the electronic meter.
- Cascadocyclique® load-shedding on 3 outputs.
- Circuit-breaker caliber selector knob (15 A to 90 A).
- GP 40 is compatible with three-phase installations (Electronic meter only).
- Dimensions: 4 modules, h = 53 mm.
- CT characteristics (ref. 2330004):
- Internal Ø: max. 10 mm.
- Rated operating current: 2 to 90 A, Cos j = 0.8 to 1.
|

|
| |
|
|
|
| |
|
|
|
|
| |
G-REYDER
G-REYDER, ENERGY MANAGER, 3 OUTPUTS, SINGLE OR THREE PHASES
Appropriate for single or three phases installations.
Cascadocyclique® load-shedding on 3 outputs, not prioritaries in single phase and on 1 output per phase in three-phase layouts.
Suitable for conventional –or pilot wire– thermal radiators, panel heaters or direct heating in general.
Features:
- 230 V, 50 Hz power supply, +/- 10%.
- 2 inputs for programmers (clocks, programming control unit, etc.).
- 1 absence input (telephone remote control).
- Pilot wire-type heating selection input.
- 1 remote information connection input (output from the Electronic meter).
- Display of the state of the dialogue with the electronic meter.
- Circuit-breaker caliber selector knob (5 A to 90 A).
- Current measure with external transformer TC-100 (as standard a single phase TC -100 is supplied, additionally it can be supplied a kit with two TC-100 for three phase installations.
|

|
| |
|
|
|
| |
|
|
| |
UNIVERSAL STAND ALONE SUPPORT WITH CASTORS FOR THERMAL RADIATORS
Features:
- Fully compatible with most of the aluminium termal radiators existing in the market.
- Powder coated RAL 9010 steel structure.
- Not recommended for radiators which weight exceed of 40 kg.
|

|
| |
|
|
|
| |
|
|
| ACCESSORIES FOR RK RANGES |
| |
TPG-IR
INFRARED REMOTE CONTROL
This remote control allows to program the set up temperatures and working hours daily and weekly to configure the performance of RKL inertia eco-fluid radiator and RKSL thermal inertia radiator ranges.
Once the program is set up in the remote control, this program can be transferred to each device in the installation. Main features:
- Set up of daily or weekly program.
- Temporally stan by mode for set up program by imposition of a new set up temperature by a limited period of time.
Features:
- LCD display backlight in blue.
- Daily and weekly program. Three pre-defined programs.
- Powered with two 1.5 V batteries type LR03/AAA, included.
|

|
| |
|
|
|
| |
|
|
|
|
| |
PG-4Z
MAINS BORNE SIGNALING (CPL) PROGRAMMABLE MULTI-ZONE THERMOSTAT
Four zones CPL Thermostat with both daily and weekly programmable options allowing different combinations with three levels of temperature, comfort, economy and frost-protection.
Features:
- Blue backlight LCD display.
- Five working modes selector.
- Weekly and daily programming options.
- Program copying function available.
- Display of either set-point or room.
Suitable for:
- Thermal radiators with eco fluid, RKHi and RKL ranges.
- Thermal inertia radiators, RKSHi and RKSL ranges..
|

|
| |
|
|
|
| |
|
|
|
|
| |
RG-CPL
ENERGY MANAGER SUITABLE FOR MAINS BORNE SIGNALING, SINGLE AND THREE PHASES
Power manager appropriate for heaters monitored with mains borne signaling control units, CPL, with individual receptors. This manager does not require receptors’ interconnection.
Features:
- It manages from 1 to 8 outputs in both one-phase or three-phase installations.
Suitable for:
- Thermal radiators with eco fluid, RKHi and RKL ranges.
- Thermal inertia radiators, RKSHi and RKSL ranges.
|

|
| |
|
|
|
| |
|
|
|
|
|
|